LBC-4000 L-Band Up/Down Converter System

Revision 4

Updating Firmware

MN/LBC4000.IOM

4–7

B. Using Command‐line: 

 

• Type  “cd  c:\temp”  at  the  Command‐line  prompt  to  change  to  the  temporary 

directory created earlier using Command‐line. 
 

• Type  “dir”  to  list  the  files  extracted  to  the  temporary  directory  from  the 

downloaded archive file. 

 

The  firmware  files  have  been  successfully  downloaded  and  are  now  available 
for transfer to the LBC‐4000. 

4.4

Performing the FTP Upload Procedure

  To proceed with the firmware update procedure, assumptions are made that: 

 

The LBC‐4000 is connected to a user‐supplied, Windows‐based PC, and: 

 
o

The PC serial port is connected to the LBC‐4000 ‘J1 | COM1’ port. 

 

o

The  PC  is  running  a  terminal  emulation  program  (for  operation  of  the 

LBC‐4000 Serial interface). 

 

The latest firmware files have been downloaded or otherwise received from 

Comtech EF Data and are available on the user PC in an accessible temporary 
folder.
 

 

1. Double‐click  FLSHCAT.EXE  (filename  or  icon)  on  the  PC  desktop  to  execute 

the FLASH UPLOAD utility program. 
 

2. From  the  FLSHCAT  dialogue  box,  select  the 

pertinent  serial  port  used  for  communication 
between  the  PC  and  the  LBC‐4000  (this  example 
selects COM1, as noted at ‘

A

’.) 

 
3. Do  not  select  a  Baud  Rate  (‘

B

’)  other  than  the 

default  selection  of  38400,  unless  otherwise 
instructed by Comtech EF Data Technical Support. 

 
4. Click ‘Software Upload’ (‘

C

’).