Comtech EF Data LBC-4000 User Manual
Page 86
LBC-4000 L-Band Up/Down Converter System
Revision 4
Serial-based Remote Product Management
MN/LBC4000.IOM
6–14
Parameter
Type
Command
(Instruction Code
and
Qualifier)
Arguments for
Command or
Response to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes between
48 and 57)
Response to Command
(Target to controller)
Query
(Instruction Code
and qualifier)
Response to query
(Target to controller)
Retrieve
Alarm Status
N/A 122
bytes
alphanumeric
Query only.
Used to Query the Alarm status of the unit, where: xx = OK (no
fault) or FT (fault):
N/A
RAS_
RAS_
x….x
(see Description of
Arguments for details)
12VDC1_xx’cr’
08VDC1_xx’cr’
05VDC1_xx’cr’
12VDC2_xx’cr’
08VDC2_xx’cr’
05VDC2_xx’cr’
REFLD_xx’cr’
IFLOA_xx’cr’
RFLOA_xx’cr’
TEMPA_xx’cr’
IFLOB_xx’cr’
RFLOB_xx’cr’
TEMPB_xx’cr’’lf’
12 VDC #1 Fault.
8 VDC #1 Fault.
5 VDC #1 Fault.
12 VDC #2 Fault.
8 VDC #2 Fault.
5 VDC #2 Fault.
Ref Osc. Lock Detect Fault.*
Conv A IFLO Lock Detect Fault.
Conv A RFLO Lock Detect Fault.
Conv A Over Temperature Fault.
Conv B IFLO Lock Detect Fault.
Conv B RFLO Lock Detect Fault.
Conv B Over Temperature Fault.
*Note: REFLD is only returned if an external reference is
present.