beautypg.com

Comtech EF Data LBC-4000 User Manual

Page 86

background image

LBC-4000 L-Band Up/Down Converter System

Revision 4

Serial-based Remote Product Management

MN/LBC4000.IOM

6–14

Parameter

Type

Command

(Instruction Code

and

Qualifier)

Arguments for

Command or

Response to Query

Description of Arguments

(Note that all arguments are ASCII numeric codes between

48 and 57)

Response to Command

(Target to controller)

Query

(Instruction Code

and qualifier)

Response to query

(Target to controller)

Retrieve
Alarm Status

N/A 122

bytes

alphanumeric

Query only.

Used to Query the Alarm status of the unit, where: xx = OK (no
fault) or FT (fault):

N/A

RAS_

RAS_
x….x

(see Description of
Arguments for details)

12VDC1_xx’cr’
08VDC1_xx’cr’
05VDC1_xx’cr’
12VDC2_xx’cr’
08VDC2_xx’cr’
05VDC2_xx’cr’
REFLD_xx’cr’
IFLOA_xx’cr’
RFLOA_xx’cr’
TEMPA_xx’cr’
IFLOB_xx’cr’
RFLOB_xx’cr’
TEMPB_xx’cr’’lf’

12 VDC #1 Fault.

8 VDC #1 Fault.
5 VDC #1 Fault.
12 VDC #2 Fault.
8 VDC #2 Fault.
5 VDC #2 Fault.
Ref Osc. Lock Detect Fault.*
Conv A IFLO Lock Detect Fault.
Conv A RFLO Lock Detect Fault.
Conv A Over Temperature Fault.
Conv B IFLO Lock Detect Fault.
Conv B RFLO Lock Detect Fault.
Conv B Over Temperature Fault.

*Note: REFLD is only returned if an external reference is