Comtech EF Data MBT-4000 User Manual
Page 65

MBT-4000 Multi-Band Transceiver System
Revision 4
Remote Control
MN/MBT4000.IOM
A–21
Parameter
Type
Command
(Instruction
Code and
qualifier)
Valid on
MBT,
BDC, or
BUC
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Serial Number N/A
All
9 bytes,
numeric
000000000 to
999999999
Query only.
Used to Query the units 9 digit serial number.
Slave returns its S/N, in the form xxxxxxxxx.
Example: RSN=000000165
N/A RSN?
RSN= x….x
(see description
for details of
arguments)
Retrieve
Utility Status
N/A MBT
24
bytes
alphanumeric
Query only.
Used to Query the utility status of the MBT-4000 base unit..
Example:
<0001/RUS={cr}
>0001/RUS={cr}{lf}
ADR=0001{cr}
BDR=9600{cr}{lf}
N/A RUS?
RUS=x….x
(see description
for details of
arguments)
Remote Baud
Rate
SBR=xxxx MBT 4
bytes,
Command or Query.
Set remote baud rate as follows:
9600 = 9600 baud
19K2 = 19200 baud
SBR= (message OK)
SBR? (received OK,
but invalid arguments
found)
SBR! (Command not
accepted by BUC
and BDC sub-units.)
SBR?
SBR=xxxx
(same format as
command
arguments)
Summary
Fault Status
N/A All
N/A
Query only.
Used to Query the status of the Summary Fault Relay, where:
0=OK
1=FT
Example: SFS?
N/A SFS?
SFS=x
(see description
for details of
arguments)
Remote
Address
SPA=xxxx MBT 4
byte,
numeric
Command or Query.
Set Physical Address-between 0001 to 9999.
Resolution 0001
Example: SPA=0412
SPA= (message OK)
SPA? (received OK,
but invalid arguments
found)
SPA! (Command not
accepted by BUC
and BDC sub-units.)
SPA?
SPA=xxxx
(same format as
command
arguments)