beautypg.com

Comtech EF Data MBT-4000 User Manual

Page 63

background image

MBT-4000 Multi-Band Transceiver System

Revision 4

Remote Control

MN/MBT4000.IOM

A–19

Parameter

Type

Command

(Instruction

Code and

qualifier)

Valid on

MBT,

BDC, or

BUC

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are ASCII numeric codes – i.e.,

ASCII codes between 48 and 57)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

qualifier)

Response to

Query

(Target to

Controller)

Reference
Oscillator
Adjust

REF=xxxx MBT 4

bytes,

numeric

Command or Query.
Ref Osc Adjust, between 0000 and 0255.
Resolution 0001.

Example: REF=0197

Note: REF cannot be adjusted when the unit is locked to an
external reference source.

REF= (message OK)
REF? (received OK,
but invalid arguments
found)
REF* (message OK,
but not permitted in
current mode)

REF? REF=xxxx

(same format as
command
arguments)

Retrieve
Equipment
Type

N/A All

22

bytes,

alphanumeric

Query only.
The unit returns a string indicated the Model Number and the
software version installed

Example: RET=BUC-4000 VER:1.0.3

N/A RET?


RET=x….x
(see description
for details of
arguments)