Comtech EF Data MBT-4000 User Manual
Page 58

MBT-4000 Multi-Band Transceiver System
Revision 4
Remote Control
MN/MBT4000.IOM
A–14
Parameter
Type
Command
(Instruction
Code and
qualifier)
Valid on
MBT,
BDC, or
BUC
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
LNA Current
Window
LCW=sxx MBT
s=1 byte,
value of 1, 2
1=LNA A
2=LNA B
xx=2 bytes,
numeric
Command or Query.
This command allows the user to set the alarm window in
± % of
the calibrated LNA Current. Valid inputs are 20 to 50 in
increments of 1%. In addition, setting the value to 99 disables
the alarm function.
Default is Disabled.
Example: LCW=130, set alarm window for LNA A (Aux Comm
1) to
± 30%.
LCW= (message ok)
LCW? (received ok,
but invalid arguments
found)
LCW* (message ok,
but not permitted in
current mode)
LCW! (command not
accepted by BUC or
BDC sub-units)
LCW?s LCW=sxx
(same format as
command
arguments)
LNA Fault
Logic
LFL=sx MBT
s=1 byte,
value of 1, 2
1=LNA A
2=LNA B
x=1 byte,
Value of 0, 1
0 = Disable
1 = Enable
Command or Query.
Allows LNA Fault Logic to contribute to the summary fault relay,
where:
s = Source:
1=LNA A (Aux Comm 1)
2=LNA B (Aux Comm 2)
x = Enable:
0 = Disabled
1 = Enabled
Example: LFL=11
LFL= (message ok)
LFL? (received ok,
but invalid arguments
found)
LCS* (message ok,
but not permitted in
current mode)
LFL! (command not
accepted by BUC or
BDC sub-units)
LFL?s
s=1 byte,
Value of 1, 2
LFL=sx
(same format as
command
arguments)
LNA Fault
Logic
LFL=x BDC
x=1
byte,
Value of 0, 1
0 = Disable
1 = Enable
Command or Query.
Allows LNA Fault Logic to contribute to the summary fault relay
as follows:
Enable
0 = Disabled
1 = Enabled
Example: LFL=1
LFL= (message ok)
LFL? (received ok,
but invalid arguments
found)
LCS* (message ok,
but not permitted in
current mode)
LFL! (command not
accepted by BDC
sub-units)
LFL?
LFL=x
(same format as
command
arguments)