beautypg.com

Comtech EF Data MBT-4000 User Manual

Page 52

background image

MBT-4000 Multi-Band Transceiver System

Revision 4

Remote Control

MN/MBT4000.IOM

A–8

Parameter

Type

Command

(Instruction

Code and

qualifier)

Valid on

MBT,

BDC, or

BUC

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are ASCII numeric codes – i.e.,

ASCII codes between 48 and 57)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

qualifier)

Response to

Query

(Target to

Controller)

Concise Alarm
Status

N/A All

20

bytes,

numeric

Query only.
Used to query the alarm status of the unit.

Example: <0001/CAS?{cr}
>0001/CAS=abcdefghijkl{cr}{lf}
Where:
a through l = 0 or 1, 0=OK, 1=FLT

All:
a=+15V Power Supply
b=+7.5V Power Supply
c=+5.0V Power Supply

MBT-4000:
d=+28V Power Supply
e=Ref Oscillator Lock Detect
f=Intermodule Communications
g=Max current on LNA power supply AUX COMM1
h=Max current on LNA power supply AUX COMM2
i=Current window LNA power supply AUX COMM1
j=Current window LNA power supply AUX COMM2
k=Fault input AUX COMM1 (Pin F, J9)
l=Fault input AUX COMM2 (Pin F, J8)

BDC/BUC:
d=X (reserved for future use)
e=Synthesizer Lock Detect
f=Heat-sink Temperature
g=LNA current (BDC only, reserved on BUC)
h=Reserved, always zero
i-l=Not sent.

N/A CAS?

CAS=x…X
(see description