Comtech EF Data MBT-4000 User Manual
Page 52

MBT-4000 Multi-Band Transceiver System
Revision 4
Remote Control
MN/MBT4000.IOM
A–8
Parameter
Type
Command
(Instruction
Code and
qualifier)
Valid on
MBT,
BDC, or
BUC
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Concise Alarm
Status
N/A All
20
bytes,
numeric
Query only.
Used to query the alarm status of the unit.
Example: <0001/CAS?{cr}
>0001/CAS=abcdefghijkl{cr}{lf}
Where:
a through l = 0 or 1, 0=OK, 1=FLT
All:
a=+15V Power Supply
b=+7.5V Power Supply
c=+5.0V Power Supply
MBT-4000:
d=+28V Power Supply
e=Ref Oscillator Lock Detect
f=Intermodule Communications
g=Max current on LNA power supply AUX COMM1
h=Max current on LNA power supply AUX COMM2
i=Current window LNA power supply AUX COMM1
j=Current window LNA power supply AUX COMM2
k=Fault input AUX COMM1 (Pin F, J9)
l=Fault input AUX COMM2 (Pin F, J8)
BDC/BUC:
d=X (reserved for future use)
e=Synthesizer Lock Detect
f=Heat-sink Temperature
g=LNA current (BDC only, reserved on BUC)
h=Reserved, always zero
i-l=Not sent.
N/A CAS?
CAS=x…X
(see description
for details of
arguments)