MBT-4000 Multi-Band Transceiver System

Revision 4

Remote Control

MN/MBT4000.IOM

A–2

A.3

RS-232

This is a much simpler configuration in which the Controller device is connected directly to the
Target via a two-wire-plus-ground connection. Controller-to-Target data is carried, via RS-232
electrical levels, on one conductor, and Target-to-Controller data is carried in the other direction
on the other conductor.

A.4

Basic Protocol

Whether in RS-232 or RS-485 mode, all data is transmitted as asynchronous serial characters,
suitable for transmission and reception by a UART. The asynchronous character is fixed at 8-N-1
(8 data bits, no parity, one stop bit). Only two baud rates are supported: 9600 baud and 19200 baud.

All data is transmitted in framed packets. The Controller is assumed a PC or ASCII dumb
terminal that is in charge of the process of monitor and control. The Controller is the only device
that is permitted to initiate, at will, the transmission of data. Targets are only permitted to transmit
when they have been specifically instructed to do so by the Controller.

All bytes within a packet are printable ASCII characters, less than ASCII code 127. In this
context, the Carriage Return and Line Feed characters are considered printable.

All messages from Controller-to-Target require a response – with one exception: This will be either to
return data that has been requested by the Controller, or to acknowledge reception of an instruction to
change the configuration of the Target. The exception to this is when the Controller broadcasts a
message (such as Set Time/Date) using Address 0, when the Target is set to RS-485 mode.

A.5

Packet Structure

Controller-to-Target

Start of

Packet

Target

Address

Address

Delimiter

Instruction

Code

Code

Qualifier

Optional

Arguments

End of Packet

<

ASCII code 60

(1 character)


(4 or 6

characters)

/

ASCII code 47

(1 character)


(3 characters)

= or ?

ASCII codes

61 or 63

(1 character)


(n characters)

Carriage Return

ASCII code 13

(1 character)

Example: <0412/MUT=1{CR}

Target-to-Controller

Start of

Packet

Target

Address

Address

Delimiter

Instruction

Code

Code

Qualifier

Optional

Arguments

End of Packet

>

ASCII code 62

(1 character)

(4 or 6

characters)

/

ASCII code 47

(1 character)

(3 characters)

=, ?, !, or *

ASCII codes

61,63,33 or 42

(1 character)

(From 0 to n

characters)

Carriage Return,

Line Feed

ASCII codes

13,10

(2 characters)

Example: >0412/MUT={CR}{LF}