3.2.1.6 UNIT 2 COMM (J6)

The J6 UNIT 2 COMM connector is used for connecting the MBT-4000
Base Module Unit 2 section to the J6 COMM connector featured on both
the BUC-4000 Block Up Converter and BDC-4000 Block Down Converter
Modules, via the 15-15 Power & Signal Harness (CEFD P/N
CA/WR10963-1), as shown in Figure 3-3.

Table 3-6. UNIT 2 COMM (J6) Connector Pinouts

Pin

Signal

A SUM

FLT

M RxD

BXC

C Tx+

BXC

D GND

E +7.5V

F +7.5V

G +15V

H GND

J Rx+

BXC

K Rx-

BXC

L Tx-

BXC

B TxD

BXC

N SPARE

P

10 MHz REF

R SPARE

NOTE – Mating Connector

CEFD P/N CN/8LT5-15B15PN













Figure 3-3. Unit 2 Base Module to Converter Module Connection