Comtech EF Data MBT-4000 User Manual
Page 61

MBT-4000 Multi-Band Transceiver System
Revision 4
Remote Control
MN/MBT4000.IOM
A–17
Parameter
Type
Command
(Instruction
Code and
qualifier)
Valid on
MBT,
BDC, or
BUC
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Retrieve
Alarm Status
N/A
All
92 bytes MBT-
4000
64 bytes
(BUC),
74 bytes
(BDC),
alphanumeric
Query only.
Used to Query the Alarm status of the unit
Example for MBT-4000 base:
<0001/RAS?{cr}
>0001/RAS={cr}
15VT1=OK{cr}
7V5T1=OK{cr}
5VLT1=OK{cr}
28VT1=OK{cr}
REFLD=OK{cr}
IICST=OK{cr}
LNAC1=OK{cr}
LNAC2=OK{cr}
LNAW1=OK{cr}
LNAW2=OK{cr}
LNAI1=OK{cr}
LNAI2=OK{cr}{lf}
Example for BDC or BUC:
<0001A1/RAS?{cr}
>0001A1/RAS={cr}
15VLT=OK{cr}
7V5LT=OK{cr}
5VOLT=OK{cr}
REFLD=XX {cr} (reserved for future use)
SYNLD=OK{cr}
HSTMP=OK{cr}
LNACR=OK{cr}{lf}
Note: LNACR will only appear for BDC.
N/A RAS?
RAS=x….x
(see description
for details of
arguments)