Multi Color Contrast Sensor Installation Instructions

Sensor Installation - Option No. 420014

1. Disconnect sensor cable from existing sensor.

2. Cut sensor cable tie holding the sensor cable to the tie holder attached to the

frame.

3. Remove existing sensor mount bracket. Retain the mounting hardware. (2

#8-32 SHCS and 2 # 8 flat washers)

4. Fasten Item 5 (Bracket, Sensor Mtg.) to the frame using the saved hardware.

5. Assemble Items 1, 2, 3 and 4 (Sensor, Bracket Guide, Sensor Slide and #10

Screws Respectively) as shown in the attached catalog pages.

6. Align Item 3 (Sensor Slide) with slot in Item 5 (Bracket, Sensor Mtg.) and

install Items 6, 7 and 8 (#10 Flat Washer, #10 SHCS x 3/8” and Thumbscrew
Knob).

7. Replace existing cable with new cable (421142 supplied). Replace all cable

ties.

8. Connect the sensor cable to the Sensor. Position the sensor to its farthest

position.

9. Cable tie sensor cable to the tie holder attached to the frame