Trouble Shooting •••• 24
Sonic Troubleshooting
(See Section 4-5 of Branson Manual)
Problem
Probable Cause
Remedy
A - Sonics are not working and
power supply light is off.
1 – Blown fuse
1 – Replace fuse on back end of power
supply.
2 – On / Off switch in “off”
position
2 – Move switch to “on” position
3 – Power lamp bulb burned out
3 – The lamp could be off but power supply
cooling fan is running. Unit is OK to
operate.
4 - Interface cable not plugged in
4 – Check interface cable between power
supply and SS Finisher
B - Sonic power supply is on but
no vibration is felt at the
converter in test mode.
1 - Cable to converter is bad.
1 – Replace the stack assembly.
2 - Converter is bad.
2 – Replace the stack assembly
3 - Horn is bad.
3 – Replace the stack assembly
4 - Power supply is bad.
4 – Replace power supply –
Return for rebuilding
5 - Horn assembly not connected
to power supply
5 – Check connection
C - Fabric cut is indented - but
not severed in two.
1 - Improper power setting
1 – Turn on power supply – check all
connections
2 - Power supply not turned on
2 – Turn on power supply
3 - Knife has become dull
3 – Change knife blade insert.
D - Fabric cuts on only one side.
1 - Knife anvil is not parallel with
the horn.
1 – See knife-leveling procedure in the blade
replacement section.