Trouble Shooting •••• 24

Sonic Troubleshooting

(See Section 4-5 of Branson Manual)

Problem

Probable Cause

Remedy

A - Sonics are not working and

power supply light is off.

1 – Blown fuse

1 – Replace fuse on back end of power

supply.

2 – On / Off switch in “off”

position

2 – Move switch to “on” position

3 – Power lamp bulb burned out

3 – The lamp could be off but power supply

cooling fan is running. Unit is OK to
operate.

4 - Interface cable not plugged in

4 – Check interface cable between power

supply and SS Finisher

B - Sonic power supply is on but

no vibration is felt at the
converter in test mode.

1 - Cable to converter is bad.

1 – Replace the stack assembly.

2 - Converter is bad.

2 – Replace the stack assembly

3 - Horn is bad.

3 – Replace the stack assembly

4 - Power supply is bad.

4 – Replace power supply –

Return for rebuilding

5 - Horn assembly not connected

to power supply

5 – Check connection

C - Fabric cut is indented - but

not severed in two.

1 - Improper power setting

1 – Turn on power supply – check all

connections

2 - Power supply not turned on

2 – Turn on power supply

3 - Knife has become dull

3 – Change knife blade insert.

D - Fabric cuts on only one side.

1 - Knife anvil is not parallel with

the horn.

1 – See knife-leveling procedure in the blade

replacement section.