beautypg.com

Indicator lights, On line, Sensor – Avery Dennison SS Finisher User Manual

Page 26: Error

background image

Users Manual SS Finisher

Trouble Shooting •••• 26

Indicator Lights

The AVERY DENNISON SS Finisher has three Indicator lights. These lights
are used along with the LCD display to tell the operator the current status of the
SS Finisher.

On Line

OFF

- Has not been powered on.

- Is in its power - up sequence.

- Failed the system test

ORANGE

- Passed system test

- Ready for operation.

GREEN

- Start button has been pressed - SS Finisher running

- Accumulator waiting for material.

Sensor

GREEN

- SS Finisher is stopped - light is on - sensor is positioned over a

sense mark

- Flashing light while SS Finisher is running - the sensor is in line

with the sense marks. See Color Mark Sensor Adjustment

Error

ORANGE

- System inter-lock triggered, see display for error.

- See Appendix B - Error Messages