Trouble Shooting •••• 32
Troubleshooting Electrical
Power Up / Sign On Communications
Problem
Probable Cause
Remedy
A - Machine fails to power up 1 – Incorrect power amplitude
1 - Confirm that the AC entry is configured for the
line voltage intended to be applied to the
machine. Failure to do so can damage the
machine’s internal power supply. Refer to the
“Fuse Configuration”
2 – Lack of power to the machine
2 - Check that both ends of the power cord are
securely plugged in.
2A - Confirm that the outlet the machine is plugged
into has power.
3 – Missing or blown fuse(s)
3 - Check that the fuse(s) located inside the AC
entry are present and intact. Replace as needed.
Refer to the Fuse Configuration.
4 – Unconnected cable / connector
inside machine.
4 - Power off and remove the power cord from the
AC entry. Remove the back cover and inspect
the cables and connectors to and from the power
supply. Refer to the “Electrical System
Schematic”.
B - Front panel displays no
text or nothing at all
1 – Front panel cable unplugged.
1 - Power off and remove the power cord from the
AC entry. Remove the back cover and inspect
the cables and connectors to and from the front
panel. Refer to the “Electrical System
Schematic”.
C - Front panel does not
complete diagnostic test 1.
1 – Front panel board unplugged
from the main board.
1 - Power off and remove the power cord from the
AC entry. Remove the back cover and check
connectors.
D - Stock does not advance
when the start button is
pressed.
1 – An interlock condition exists.
1 - Determine the number and type of interlock(s)
by reading the front panel display. As each is
corrected, the number of errors will decrease.
2 – Tag length or Offset values are
invalid.
2 - Check values located in front panel and adjust.
3 – Feed motor unplugged or faulty 3 - Check feed motor cable and/or replace feed
motor.
4 – Feed roller not gripping stock
4 - Adjust feed pressure. Refer to “Mechanical
Adjustment of Feed Roller Pressure”.
5 – Feed rollers bound
5 - With power off, check that all rollers turn freely.
6 – Stock Bound
6 - Check that stock will pull through the printer
with little or no resistance.
E - The Stacker fails to run.
1- The stacker cable is not
connected
1 - Power off and remove the power cord from the
AC entry. Remove the back cover and inspect
the cables and connectors.
2 – Faulty Stacker Motor
2 - Replace Stacker Motor.
3 – Stacker jammed.
3 - Remove cause of the jam at the stacker.