beautypg.com

Printhead setup – Avery Dennison SNAP 656 User Manual

Page 33

background image

Users Manual Model 656/636

Control Panel Operation

••

27B

D O T S H I F T

V A L U E : ± X X N E W V A L U E : ± Y Y

This screen follows the "CHANGE CUT POSITION" screen. This screen allows the
print position to be adjusted in the WEB direction. The buttons are
used to change the new shift value. The value is displayed in a positive/negative
format. The value ranges for XX and YY can be from a -16 to a +16 dots. Pressing
ENTER will change the CURRENT DOT SHIFT value to the NEW DOT SHIFT
value. A more positive number will move the print to the front while a more negative
number will move the print to the back.

Pressing the MODE/Down Arrow key will take the user back to the "PRINT CHECK
OUT FORMAT" screen. Pressing the EXIT/Up Arrow key will take the user back to
the "HOME" screen.

PRINTHEAD SETUP

P R E S S E N T E R F O R

P R I N T H E A D S E T U P

This screen follows the "PRINT/CUT POSITIONS" screen.

Pressing ENTER will take the user to the "PRINTHEAD SETUP" screens. Pressing
the MODE / Down Arrow key will take the user to the "CALIBRATING SENSORS"
screen. Pressing the EXIT / Up Arrow key will take the user back to the "HOME"
screen.

C H A N G E S T R O B E

V A L U E : ± X X N E W V A L U E : ± Y Y

This screen is the first screen under "PRINTHEAD SETUP" screen. This screen
allows the user to adjust the strobe. The buttons are used to change the
new value. The value is displayed in a positive/negative format. The value ranges for
X and Y can be from a -7 to a +7. Pressing ENTER will change the CURRENT
STROBE value to the NEW STROBE value. A more positive number will make the
print darker while a more negative number will make the print lighter.

Pressing the MODE/Down Arrow key will take the user to the "CHANGE HEAD
CATEGORY" screen. Pressing the EXIT / Up Arrow key will take the user back to
the "HOME" screen.

H E A D C A T E G O R Y

V A L U E : ± X X N E W V A L U E : ± Y Y

This screen follows the "CHANGE STROBE" screen. The screen allows the user to
enter the head category. The buttons are used to change the new head
category value. The value ranges from 1 to 8. Pressing ENTER will change the
CURRENT HEAD category value to the NEW HEAD value. See the section
“PRINTHEAD REPLACEMENT” for instructions for setting the head category.

Pressing the MODE / Down Arrow key will take the user back to the "CHANGE
STROBE" screen. Pressing the EXIT / Up Arrow key will take the user back to the
"HOME" screen.

This manual is related to the following products: