8B

••

Printer Setup

Users Manual Model 656/636

Fuse Configuration

The main fuse(s) on the AVERY DENNISON 656 / 636 are located inside the AC
power entry receptacle. The entry has a fuse drawer that holds the fuse(s) and selects
the appropriate line voltage. If the voltage in the window DOES NOT match the AC
line voltage intended to be supplied to the printer, DO NOT plug the power cord in.
Reconfigure as follows:

1) Using a flat blade screwdriver, open the AC entry by lifting the tab just above the

voltage indicator window.

2) Remove the red fuse drawer.

3) Remove all fuses and the fuse jumper if it is present.

4) Insert into the fuse drawer the correct number and style of fuses and fuse jumper

for your application.

Configuration Number One:

Line voltage within the range of

(See Figure 3A)

90 - 132VAC @ 50 - 60Hz

1) Install one 921167 - 10.0A 250V Fast Acting 1/4 x 1 1/4"

2) Install one Fuse Jumper

Configuration Number Two:

Line voltage within the range of

(See Figure 3B)

180 - 265VAC @ 50 - 60Hz

1) Install two 921168 10.0A 250V Fast Acting 5 x 20MM

NOTE: The fuse jumper must be removed to install both 5 x 20mm fuses.

Figure - 3A

Figure - 3B

Location of 115V Text

Location of 230V Text

Two 5 x 20MM Fuses One Each

One 1/4 x 1 1/4" Fuse Far Side

Location of 115V Text

Location of 230V Text

Fuse Jum per

5 x 20 m m fuse

FRONT

FRONT

A

B

C

The fuses must be between points A

and B as shown not B and C.

4) Reinsert the fuse drawer into the AC entry with the desired voltage up.

5) Close the AC entry and verify the correct voltage is now visible.