beautypg.com

Perational, Malfunctions, Rror – Avery Dennison ALS 350 User Manual

Page 94: Messages

background image

94

6

O

PERATIONAL

MALFUNCTIONS

6.2 E

RROR

MESSAGES

ALS

350
450

E_14

Too many products between product
sensor and dispensing edge.

Product sensor located too far from dispensing edge:
– A maximum of 7 products can be located between

the product sensor and the dispensing edge.

£

Change the position of the product sensor.

£

Subsequently correct the POS setting.

The product triggers several start signals, caused by
reflections, for example:

£

Adjust the product length (PRDL function).

E_15

Short circuit
or
Overload of outputs from CN10

A check of the connections and output signals by
servicing technicians is required; refer to the service
guide.

ER-U

Software error

£

Press the ENTER key.

£

Make note of all the information that is displayed on the
control panel.

£

Make note of what happened before the error occurred.

£

Inform Avery Dennison’s customer service.

ER-I

Software error

ER-D

Software error

ER-T

Software error

ER-A

Software error

Message

Description

Possible causes and remedies