Manually initialise the material – Avery Dennison ALS 350 User Manual

Page 47

background image

47

4

O

PERATION

4.1 A

CTIVATION

AND

SHUT

-

DOWN

ALS

350
450

The machine can also be automatically initial-
ised after switch-on by using the INIT function:

£

In the standard menu, press the NEXT or PRIOR key
until INIT [39] is displayed on the operator panel.

£

Call the INIT function by pressing the ENTER key.

£

Press and hold the FEED key.

– The message AUTO appears on the operator panel.
– The machine slowly starts up and dispenses a label.

£

Release the FEED key once a label gap has passed
the photoelectric sensor at the dispenser head.

– If the initialisation was successful, „ON“ appears on

the operator panel.

Manually initialise the material

If automatic initialisation is not possible, it does
not generally mean there is a malfunction. Man-
ual initialisation is often required if:
– the proper label stop sensor is not installed.

– transparent labels are used.
– labels with only a slight difference of trans-

parency between label and backing material
are used.

– perforated or otherwise blocked out labels

are used [40].

Only by qualified calibration technicians:

£

Calling up the extended menu.

£

Input the label distance using the LPIT
function

£

Adjust the photoelectric sensor using the
CONT function.

£

Refer to chapter OperationSettings in the
extended menu
.

[39] INIT display on the operator panel

[40] A Label distance

B Photoelectric sensor
C Labels with block outs (perforations)

A

B

C

C