2 functions in the extended menu, Please observe the following, Calling up the extended menu – Avery Dennison ALS 350 User Manual
Page 83: Applicator type (appl)

83
4.6 A
PPLICATOR
(
OPTIONAL
)
ALS
350
450
4.6.2
Functions in the extended
menu
Please observe the following:
CAUTION!
Erroneous settings can lead to production
setbacks, damage to the machine and sys-
tem, and can even cause work-related acci-
dents!
– Only specially trained and instructed per-
sonnel may alter the settings in the ex-
tended menu.
Calling up the extended menu.
£
Simultaneously press the NEXT and PRIOR keys.
– CODE appears on the LED display.
£
Enter the password [87].
– The following appears on the LED display for ap-
prox. 1 second:
* * * *
– The extended menu is active.
Applicator type
(APPL)
– Set the applicator type used or switch off the appli-
cator.
In the extended menu:
£
Call up the APPL function.
£
Set the desired type.
– Possible settings:
ASA Air Stream Applicator
EP: Electro-pneumatic applicator
REVP: Reverse electro-pneumatic applicator
DIR: Dispense directly from the dispenser head
without using the applicator
£
Confirm the setting using the ENTER key and exit
the function.
[87] Key sequence (password) for the extended menu