beautypg.com

9 product length (prdl) – Avery Dennison ALS 350 User Manual

Page 75

background image

75

4

O

PERATION

4.4 S

ETTINGS

IN

THE

EXTENDED

MENU

ALS

350
450

4.4.9

Product length

(PRDL)

A start signal can be prematurely triggered by the
shape of the product or reflective surfaces. In such a
case, the product length must be manually set.

Example [81]:
If the product [D] reaches the product sensor [C], a start
signal is sent and the machine dispenses a label. The
recesses in the product trigger additional start signals;
without the PRDL function, the product would be la-
belled several times. With the product length [A] set in
the PRDL function, the machine ignores all start signals
until the product has passed the dispenser head.

In the extended menu:

£

Call up the PRDL function.

£

Set the product length.

– Settings are possible in 1 mm steps:

Minimum: 5 mm
Maximum: 999 mm

£

Confirm the value using the ENTER key and exit the
function.

To set the product length the same as the label dis-
tance:

£

Set the value for PRDL to less than 5.

– The message AUTO appears on the operator panel.
– The control system automatically sets the value for

PRDL to the value of the label distance (LPIT).

[81] A Product length

B Label
C Product sensor
D Product with recesses (arrows)

A

D

C

B