4.4 S

ETTINGS

IN

THE

EXTENDED

MENU

ALS

350
450

Check setting

£

Call up the STOD function.

£

Set the value for STOD to „0“.

£

Confirm the value using the ENTER key and exit the
function.

£

Press the FEED key.

– A label is dispensed.
– The leading edge of the next label should rest exactly

on the dispensing edge [78].

£

Remove a single label from in front of the
sensor [79].

£

Press the FEED key.

– A label is dispensed [80A].
– The gap on the label ribbon should be automatically

compensated for [80B].

– The leading edge of the following label should rest

exactly on the dispensing edge [80C].

After the check:
– Check the label stop position (STOD); refer to

Page 55.

[78] The leading edge of the following label should rest on the dis-

pensing edge

[79] Remove a single label from in front of the sensor

[80] After pressing the FEED key:

A A label is dispensed
B The gap on the label ribbon should be automatically compen-

sated for

C The feed stops, the leading edge of the following label should

rest on the dispensing edge

A

B

C