beautypg.com

5 automatic material initialisation (init) – Avery Dennison ALS 350 User Manual

Page 59

background image

59

4

O

PERATION

4.2 S

ETTING

AND

MONITORING

ALS

350
450

4.2.5

Automatic material initiali-
sation

(INIT)

Also refer to chapter Activation and shut-down.

£

In the standard menu, press the NEXT or PRIOR key
until INIT [62] is displayed on the operator panel.

£

Call the INIT function by pressing the ENTER key.

£

Press and hold the FEED key.

– The message AUTO appears on the operator panel.
– The machine slowly starts up and dispenses a label.

£

Release the FEED key once a label gap [63 arrow]
has passed the photoelectric sensor [63A] at the
dispenser head.

If the initialisation was successful:
– „ON“ appears on the operator panel.
– When the FEED key is pressed, a label is dis-

pensed.

If the initialisation was unsuccessful:
– The message FAIL appears on the operator panel.

£

Initiate the INIT function again

or:

£

Manually initialise the material employing
qualified calibration technicians.

If the FEED key is not pressed down when INIT
is displayed on the operator panel, but only
lightly actuated:
– The values for the label distance setting and

the label stop sensor will be deleted provided
these values are stored in the control unit.

– Continual feed at maximum speed is trig-

gered.

– The continual feed only stops after a mal-

function occurs.

£

To prevent operational malfunctions, switch
off the machine at the main switch as soon
as possible.

[62] INIT display on the operator panel

[63] Initialise the label material