5 automatic material initialisation (init) – Avery Dennison ALS 350 User Manual
Page 59

59
4.2 S
ETTING
AND
MONITORING
ALS
350
450
4.2.5
Automatic material initiali-
sation
(INIT)
Also refer to chapter Activation and shut-down.
£
In the standard menu, press the NEXT or PRIOR key
until INIT [62] is displayed on the operator panel.
£
Call the INIT function by pressing the ENTER key.
£
Press and hold the FEED key.
– The message AUTO appears on the operator panel.
– The machine slowly starts up and dispenses a label.
£
Release the FEED key once a label gap [63 arrow]
has passed the photoelectric sensor [63A] at the
dispenser head.
If the initialisation was successful:
– „ON“ appears on the operator panel.
– When the FEED key is pressed, a label is dis-
pensed.
If the initialisation was unsuccessful:
– The message FAIL appears on the operator panel.
£
Initiate the INIT function again
or:
£
Manually initialise the material employing
qualified calibration technicians.
If the FEED key is not pressed down when INIT
is displayed on the operator panel, but only
lightly actuated:
– The values for the label distance setting and
the label stop sensor will be deleted provided
these values are stored in the control unit.
– Continual feed at maximum speed is trig-
gered.
– The continual feed only stops after a mal-
function occurs.
£
To prevent operational malfunctions, switch
off the machine at the main switch as soon
as possible.