beautypg.com

12 number of unlabelled products (mlab), 12 number of unlabelled products, Mlab) – Avery Dennison ALS 350 User Manual

Page 77: 13 electronic transmission ratio of the rpm trans, Mitter (egra)

background image

77

4

O

PERATION

4.4 S

ETTINGS

IN

THE

EXTENDED

MENU

ALS

350
450

4.4.12

Number of unlabelled products
(MLAB)

If products do not get labelled, the operator receives
the warning message W_0 at the operator panel. If too
many products in a row do not get labelled, the machine
stops. The error message E_11 appears at the opera-
tor panel. Using the MLAB function, you can determine
how many products in a row are allowed to be unla-
belled before the machine stops.

Example [84]:
MLAB is set to value 2. The machine stops after three
products in a row are not labelled. The error message
E__11 appears on the operator panel.

In the extended menu:

£

Call up the MLAB function.

£

Set the desired value.

– Possible settings: 0 ... 10 products

£

Confirm the setting using the ENTER key and exit
the MLAB function.

4.4.13

Electronic transmission ratio
of the RPM transmitter (EGRA)

– Compensation factor for RPM transmitter when op-

erating with automatic dispensing speed adjustment

– Refer to Chapter Automatic dispensing speed

(APSF), Page 80.

[84] Three products in a row were not labelled.

This manual is related to the following products: