4.2 S

ETTING

AND

MONITORING

ALS

350
450

4.2.3

Dispensing speed

(VELO)

As a rule, the labelling speed must correspond to the
product speed. Depending on the operating conditions,
the labelling speed can also be set somewhat higher in
unique cases.

Prerequisites:
– The label stop position (STOD) is correctly set.

£

In the standard menu, press the NEXT [57A] or
PRIOR [57B] key until VELO [58] is displayed on
the operator panel.

£

Call up the VELO function by pressing the
ENTER [57C] key.

– The current speed is displayed on the operator pan-

el in m/min.

£

Change the labelling speed using the NEXT or
PRIOR key.

– Settings are possible in steps of 0.1 m/min:

Minimum: 0.5 m/min
Maximum: 55 m/min

£

Confirm the desired value using the ENTER key and
exit the VELO function.

Test the setting:

£

Remove the pressure roller unit at the dispensing
edge.

£

Start the system and only label one product.

– The labelling speed is too low if the product pulls the

label away from the backing material.

– The labelling speed is too high if the label on the

product has folds in it.

Automatic dispensing speed (optional)

If the automatic dispensing speed (APSF) is activated:
– Only display of the current speed using the VELO

function.

– Manual setting of the dispensing speed is not possi-

ble.

– For further information on the APSF function, see

chapter 4 OperationAutomatic dispensing speed
(APSF)
Page 80.

[57] Symbols on the operator panel keys

A NEXT key
B PRIOR key
C ENTER key

[58] VELO display on the operator panel

A

C

B