beautypg.com

Prerequisites, Start dispensing labels, Prerequisites start dispensing labels – Avery Dennison ALS 350 User Manual

Page 52

background image

52

4

O

PERATION

4.1 A

CTIVATION

AND

SHUT

-

DOWN

ALS

350
450

Prerequisites

– Both machines are configured and tested for tan-

dem operation and automatic dispensing speed ad-
justment.

– Label material is inserted, machines are switched

on, material is initialised.

– „OFF“ appears on the operator panels of both ma-

chines.

On the machine that is to begin labelling first:

£

Press the ENTER key [48B].

– The operator panel of this machine indicates

ON [48A]. This machine is activated.

On the other machine:

£

Press the ENTER key.

– The operator panel of this machine indicates LOCK.

Start dispensing labels

– The conveyor belt starts up. The first product reach-

es the product sensor [49A] of the activated ma-
chine.

– The product sensor sends a start signal.
– The machine with the ON indication starts dispens-

ing labels [49B].

– The machine with the LOCK indication remains in

standby [49C].

[48] Operator panel

A „ON“ LED indicator
B ENTER key

[49] Start of the label dispensing in tandem operation:

A The first product has reached the product sensor of the ma-

chine that is to begin labelling first.

B The machine with the ON indication starts dispensing labels.
C The machine with the LOCK indication remains in standby.

A

B

B

C

A