6 serial over lan configuration, Table 4-48, Fan resource - control state – Artesyn System Management Interface Based on HPI-B (Centellis CO 31kX-4100-2000-4410) (June 2014) User Manual
Page 84: Serial over lan configuration, Using hpi-b

Using HPI-B
System Management Interface Based on HPI-B (Centellis CO31kX/4100/2000/4410) User’s Guide
84
4.6
Serial Over LAN Configuration
The ATCA-M100, ATCA-MF105, and SAM-1410 has the capability to automatically configure
the Serial Over LAN (SOL) feature as specified for IPMI V2.0. The SOL feature, for example,
allows you to view the boot process and the BIOS settings of a blade and to change BIOS
settings if necessary.
Whenever a front blade is discovered in the shelf, the ATCA-M100/ATCA-MF105/SAM-1410
checks whether the blade supports SOL. If it does support SOL, the ATCA-M100/ATCA-
MF105/SAM-1410 performs all configuration steps necessary to use the SOL feature.
This includes the following:
1. Configure an IPMI user
2. Configure user privileges
3. Configure LAN channel parameters
4. Configure SOL parameters
The most significant parameters to configure are the IP addresses of the LAN channels. These
are calculated according to the following formula:
TypeUnion.Analog.Default
Default blower speed level
DefaultMode.Mode
SAHPI_CTRL_MODE_AUTO
DefaultMode.ReadOnly
SAHPI_TRUE
WriteOnly
SAHPI_FALSE
Table 4-48 Fan Resource - Control State
SaHpiCtrlStateT
Value
Type
SAHPI_CTRL_TYPE_ANALOG
StateUnion.Analog
Current blower speed level
Table 4-47 Fan Resource - Control (continued)
SaHPICtrlRecT
Value