Table 4-45, Fan resource - entity path and id string, Table 4-46 – Artesyn System Management Interface Based on HPI-B (Centellis CO 31kX-4100-2000-4410) (June 2014) User Manual
Page 83: Fan resource - rdr, Table 4-47, Fan resource - control, Using hpi-b

Using HPI-B
System Management Interface Based on HPI-B (Centellis CO31kX/4100/2000/4410) User’s Guide
83
As mentioned above, each domain furthermore contains HPI resources which represent fans in
a shelf. There is one fan resource for each fan. The fan resources allow you to control the fan
speeds of individual fans. The entity paths and ID strings of these resources are given in the
following table. The control mode of an individual fan cannot be changed, it will always be the
same mode as the mode of the virtual cooling control.
The RDR definitions are given in the following two tables.
Table 4-45 Fan Resource - Entity Path and ID String
Property
Entity Path
Entity Path
{ADVANCEDTCA_CHASSIS,
ID String
FAN MODULE
Table 4-46 Fan Resource - RDR
SaHpiRdrT
Value
RecordId
Assigned by HPI
RdrType
SAHPI_CTRL_RDR
Entity
Fan resource entity
IsFru
Unused
RdrTypeUnion
CtrlRec
See
Table "Fan Resource - Control" on page 83
IdString
Fan 0 Control
Table 4-47 Fan Resource - Control
SaHPICtrlRecT
Value
Num
MOTHPI_CTRL_NUM_FAN
OutputType
SAHPI_CTRL_FAN_SPEED
Type
SAHPI_CTRL_TYPE_ANALOG
TypeUnion.Analog.Min
Minimum blower speed level
TypeUnion.Analog.Max
Maximum blower speed level