8 hpi daemon switchover control, Table 4-25, Active and stand-by hpi daemon sensors event state – Artesyn System Management Interface Based on HPI-B (Centellis CO 31kX-4100-2000-4410) (June 2014) User Manual
Page 66: Table 4-26, Hpi daemon failover control rdr, Using hpi-b
Using HPI-B
System Management Interface Based on HPI-B (Centellis CO31kX/4100/2000/4410) User’s Guide
66
4.4.8
HPI Daemon Switchover Control
This HPI control handles the switchover between the active and deactivated HPI-B daemon.
The location (active/deactivated) of the HBI daemon cannot be controlled directly. Instead,
this HPI control can be used to initiate a switchover. After the switchover is completed, if
eventing is enabled for the active HPI-B daemon sensor, the HPI Implementation will send an
event with the Resource Id of the new Resource hosting the active HBP daemon.
Note that the initiation of a switchover is meaningful only when the state of the HPI daemon
redundancy sensor is SAHPI_ES_FULLY_REDUNDANT. If there is no standby HPI daemon
present, an attempt to initiate a switchover will return the error code
SA_ERR_HPI_INVALID_REQUEST.
Type
SAHPI_SENSOR_READING_TYPE_UINT64
Value
ResourceId in least significant 32 bits if one is present,
otherwise SAHPI_UNSPECIFIED_RESOURCE_ID
Table 4-25 Active and Stand-By HPI Daemon Sensors Event State
SaHpiEventStateT
Value
EventState
SAHPI_ES_PRESENT | SAHPI_ES_ABSENT
Table 4-24 Active and Stand-By HPI Daemon Sensors Reading (continued)
SaHpiSensorReadingT
Value
Table 4-26 HPI Daemon Failover Control RDR
SaHpiRdrT
Value
Notes
RecordId
Assigned by HPI implementation
RdrType
SAHPI_CTRL_RDR
Entity
Same as Shelf Manager Resource
IsFru
SAHPI_FALSE
RdrTypeUnion.CtrlRec.Num
MOTHPI_CTRL_SWITCHOVER_DAEMON_
NUM
RdrTypeUnion.CtrlRec.Type
SAHPI_CTRL_TYPE_DIGITAL
RdrTypeUnion.CtrlRec.OutputType
SAHPI_CTRL_GENERIC