Using HPI-B

System Management Interface Based on HPI-B (Centellis CO31kX/4100/2000/4410) User’s Guide

66

4.4.8

HPI Daemon Switchover Control

This HPI control handles the switchover between the active and deactivated HPI-B daemon.
The location (active/deactivated) of the HBI daemon cannot be controlled directly. Instead,
this HPI control can be used to initiate a switchover. After the switchover is completed, if
eventing is enabled for the active HPI-B daemon sensor, the HPI Implementation will send an
event with the Resource Id of the new Resource hosting the active HBP daemon.

Note that the initiation of a switchover is meaningful only when the state of the HPI daemon
redundancy sensor is SAHPI_ES_FULLY_REDUNDANT. If there is no standby HPI daemon
present, an attempt to initiate a switchover will return the error code
SA_ERR_HPI_INVALID_REQUEST.

Type

SAHPI_SENSOR_READING_TYPE_UINT64

Value

ResourceId in least significant 32 bits if one is present,
otherwise SAHPI_UNSPECIFIED_RESOURCE_ID

Table 4-25 Active and Stand-By HPI Daemon Sensors Event State

SaHpiEventStateT

Value

EventState

SAHPI_ES_PRESENT | SAHPI_ES_ABSENT

Table 4-24 Active and Stand-By HPI Daemon Sensors Reading (continued)

SaHpiSensorReadingT

Value

Table 4-26 HPI Daemon Failover Control RDR

SaHpiRdrT

Value

Notes

RecordId

Assigned by HPI implementation

RdrType

SAHPI_CTRL_RDR

Entity

Same as Shelf Manager Resource

IsFru

SAHPI_FALSE

RdrTypeUnion.CtrlRec.Num

MOTHPI_CTRL_SWITCHOVER_DAEMON_

NUM

RdrTypeUnion.CtrlRec.Type

SAHPI_CTRL_TYPE_DIGITAL

RdrTypeUnion.CtrlRec.OutputType

SAHPI_CTRL_GENERIC