3 setting up hpi clients, Software installation and configuration – Artesyn System Management Interface Based on HPI-B (Centellis CO 31kX-4100-2000-4410) (June 2014) User Manual
Page 30
Software Installation and Configuration
System Management Interface Based on HPI-B (Centellis CO31kX/4100/2000/4410) User’s Guide
30
2.3
Setting Up HPI Clients
This section describes how to install/configure HPI clients on node blades.
PowerOnSequencing
To enable/disable
power on sequencing.
Specific feature of M100
shelf manager
<0,1>
[1]
– enable
0
– disable
1
PowerBudgetComputation
Power budget
computation
<0,1>
[1]
- Follow the Power Budget
algorithm before allocating the
power
0
- No power budget algorithm
is followed
1
HPI_OEM_DISCRETE_SENSOR_
DEF_SEVERITY
HPI-B Daemon will set
the severity for the HPI
events of non-threshold
sensors based on the
value configured for this
tag.
Note: If this tag is set to
3, then change the
OPENHPI_LOG_ON_S
EV
tag to
"INFORMATIONAL"
instead of "MINOR" so
that it logs events of
"INFORMATIONAL"
severity also into DEL.
<0,1,2,3>
[3]
- informational
0
- critical
1
- major
2
- minor
Note: Commented by default,
Please uncomment in the
config file for the tag to take
effect.
0
- critical
daemon will
assign the
default "critical"
severity
for the events of
non-threshold
sensors
(discrete/OEM)
SOL and cooling related options are not described in this table. For more information on this,
refer to
and
on page
96.
Table 2-5 Plugin Specific Parameters (continued)
Tag
Description
Allowed values
Default in Config. file
Built-in Default