AMETEK XBT Series User Manual
Page 48

Remote Interface Protocol and Package Mode
SOUR:VOLTAGE3:PROT 12
==> set over voltage to 12V for channel 3.
SOURCE:VOLT1:PROT 30
==> set over voltage to 30V for channel 1.
SOUR:VOLT2:PROTECTION 10
==> set over voltage to 10V for channel 2.
VOLTAGE3:PROT 7
==> set over voltage to 7V for channel 3.
VOLT2:PROT 18
==> set over voltage to 18V for channel 2.
VOLT1:PROTECTION 27
==> set over voltage to 27V for channel 1.
VOLT:PROTECTION 25
==> set over voltage to 25V for channel 1.
OVSET2 19
==> set over voltage to 19V for channel 2.
How to define over current protection:
SOUR:CURRENT3:PROT 1.2
==> set over current to 1.2A for channel 3
SOURCE:CURR1:PROT 3
==> set over current to 3A for channel 1
SOUR:CURR2:PROTECTION 2
==> set over current to 2A for channel 2
CURRENT3:PROT 2.7
==> set over current to 2.7A for channel 3
CURR2:PROT 1.8
==> set over current to 1.8A for channel 2
CURR1:PROTECTION 2.7
==> ses over current to 2.7A for channel 1
CURR:PROTECTION 2.5
==> set over current to 2.5A for channel 1
OISET2 1.9
==> set over current to 1.9A for channel 2.
How to read back over voltage parameter:
SOUR:VOLTAGE3:PROT? ==>
return over voltage for channel 3
SOURCE:VOLT1:PROT? ==>
return over voltage for channel 1
SOUR:VOLT2:PROTECTION? ==>
return over voltage for channel 2
VOLTAGE3:PROT? ==>
return
over voltage for channel 3
VOLT2:PROT?
==> return over voltage for channel 2
VOLT1:PROTECTION?
==> return over voltage for channel 1
VOLT:PROTECTION?
==> return over voltage for channel 1
OVSET2?
==> return over voltage for channel 2
How to read back over current parameter:
SOUR:CURRENT3:PROT? ==>
return over current for channel 3
SOURCE:CURR1:PROT? ==>
return over current for channel 1
SOUR:CURR2:PROTECTION? ==>
return over current for channel 2
CURRENT3:PROT? ==>
return
over current for channel 3
CURR2:PROT? ==>
return
over current for channel 2
5-14