Remote Interface Protocol and Package Mode

SOUR:VOLTAGE3:PROT 12

==> set over voltage to 12V for channel 3.

SOURCE:VOLT1:PROT 30

==> set over voltage to 30V for channel 1.

SOUR:VOLT2:PROTECTION 10

==> set over voltage to 10V for channel 2.

VOLTAGE3:PROT 7

==> set over voltage to 7V for channel 3.

VOLT2:PROT 18

==> set over voltage to 18V for channel 2.

VOLT1:PROTECTION 27

==> set over voltage to 27V for channel 1.

VOLT:PROTECTION 25

==> set over voltage to 25V for channel 1.

OVSET2 19

==> set over voltage to 19V for channel 2.

How to define over current protection:

SOUR:CURRENT3:PROT 1.2

==> set over current to 1.2A for channel 3

SOURCE:CURR1:PROT 3

==> set over current to 3A for channel 1

SOUR:CURR2:PROTECTION 2

==> set over current to 2A for channel 2

CURRENT3:PROT 2.7

==> set over current to 2.7A for channel 3

CURR2:PROT 1.8

==> set over current to 1.8A for channel 2

CURR1:PROTECTION 2.7

==> ses over current to 2.7A for channel 1

CURR:PROTECTION 2.5

==> set over current to 2.5A for channel 1

OISET2 1.9

==> set over current to 1.9A for channel 2.

How to read back over voltage parameter:

SOUR:VOLTAGE3:PROT? ==>

return over voltage for channel 3

SOURCE:VOLT1:PROT? ==>

return over voltage for channel 1

SOUR:VOLT2:PROTECTION? ==>

return over voltage for channel 2

VOLTAGE3:PROT? ==>

return

over voltage for channel 3

VOLT2:PROT?

==> return over voltage for channel 2

VOLT1:PROTECTION?

==> return over voltage for channel 1

VOLT:PROTECTION?

==> return over voltage for channel 1

OVSET2?

==> return over voltage for channel 2

How to read back over current parameter:

SOUR:CURRENT3:PROT? ==>

return over current for channel 3

SOURCE:CURR1:PROT? ==>

return over current for channel 1

SOUR:CURR2:PROTECTION? ==>

return over current for channel 2

CURRENT3:PROT? ==>

return

over current for channel 3

CURR2:PROT? ==>

return

over current for channel 2

5-14