Remote Interface Protocol and Package Mode

[ state/bool]

ON/1 (enable) or OFF/0 (disable) OCP

:VOLTage[n]

Sets the floating point value of the DC output
voltage in volts for channel n: 1 - 3.

[ level]

voltage level: 0 – 32V for ch1 and ch2, 0 – 15V
for ch3

:PROTection

over voltage protection (OVP)

[?/ level]

return or set the over voltage in volts

:TRIGger

trigger voltage protection

[ state/bool]

ON/1 (enable) or OFF/0 (disable) OVP

EXAMPLES:

How to set tracking mode:

OUT:TRACK

How to set serial output mode:

OUT:SER
OUT:SERIAL

How to set parallel output mode:

OUT:PARA
OUT:PARALLEL

How to resume normal output mode:

OUT:NORM
OUT:NORMAL

How to read back machine status:

STATUS?

How to read back machine error code:

STAT:ERR?
STATUS:ERR?
STATUS:ERROR?

5-8