AMETEK XBT Series User Manual
Page 39

Remote Interface Protocol and Package Mode
:ERRor[?]
read back machine error code
:CCP[?]
read back Iset DAC value
:CVP[?]
read back Vset DAC value
:MONV[?]
read back Vout DAC value
:MONI[?]
read back Iout DAC value
PROGram program
subsystem
[ state/bool]
ON/1 (enable) or OFF/0 (disable) program
action
[ n]
select [n] as the program number, n range from
0 ~ 99
:VSET[n]
volt setting for channel n: 1 - 3
[ level]
voltage level: 0 – 32V for ch1 and ch2, 0 – 15V
for ch3
:ISET[n]
current setting for channel n: 1 - 3
[ level]
current level: 0 – 3A for ch1 and ch2, 0 – 5A for
ch3
:TIMER
return or set up timer
[?/ hh:mm:ss]
:FASTimer
set up timer for fast action
[ level]
unit is millisecond, range from 4~65535ms
:NEXT
next step
[?]
return the next program number
:END
end current program
:NEXT
next program number = current program
number + 1
:JUMP[ n]
jump to program number n: 0 ~ 99
:SAVe
save programmable 0 ~ programmable 99 value
TIMer
timer subsystem
[?]
return timer setting
[ ON/OFF]
enable/disable timer
[ hh:mm:ss]
set up timer
:TIMER?
response is current timer parameter
:PAUSE
stop running the timer
M370187-01 Rev J
5-5