AMETEK XBT Series User Manual
Page 44

Remote Interface Protocol and Package Mode
How to set up a program (example):
step 1: PROG 10
==> select program number 10, program
number shall be in 0 ~ 99.
step 2: PROG:VSET1 16V
==> set output voltage to 16v for ch1
step 3: PROG:VSET2 25V
==> set output voltage to 25v for ch2
step 4: PROG:VSET3 3.3V
==> setoutput voltage to 3.3v for ch3
step 5: PROG:ISET1 1A
==> set output current up to 1A for ch1
step 6: PROG:ISET2 2A
==> set output current up to 2A for ch2
step 7: PROG:ISET3 3.3A
==> set output current up to 3.3A for ch3
step 8: PROG:TIMER:00:05:00
==> set up the run-time to 5 minutes
step 9: PROG:NEXT:NEXT
==> next step is the next program, program
number 11 in this example
:
How to save program:
PROGRAM:SAV
PROG:SAVE
How to start program:
PROG n
==> select the program number n: 0 - 99
PROGRAM ON
==> start running the program selected in the
above command
How to close program:
PROG OFF
How to read program parameter:
PROGRAM?
==> Return program parameter
PROGRAM:TIMER? ==>
Return timer parameter
How to set memory:
step 1: MEM:1
==> select memory number is 1
step 2: MEM:VSET 1.5
==> set channel 1 output voltage to1.5 V.
step 3: MEM:ISET3 5
==> set channel 3 ouput current up to 5 A.
5-10
M370187-01 Rev J