beautypg.com

Section 7 application notes, 1 battery charging, 2 load considerations – AMETEK DCS-E 3kW Series User Manual

Page 93: 1 inductive loads

background image

M362295-01 Rev C

7-1

SECTION 7

APPLICATION NOTES

7.1 BATTERY

CHARGING

When using the DCS-E Series (3kW) power supply to charge a battery, take the following
precautions to prevent damage to the supply and/or the battery in case the overvoltage
protection (OVP) circuit is activated
.

Select a diode rated to handle the required charging current and voltage. Use the
following table as a reference.

Peak Charging Current

Maximum Voltage Diode Type

250-350A

40V

Two (2) parallel MBR30045CT

60-249A

40V

One (1) MBR30045CT

25-59A

100V

One (1) MUR7015

10-24A

300V

One (1) MUR3040PT

5-9A

500V

One (1) MUR1560

<5A

600V

One (1) MUR758

Connect the diode in series with either supply output to prevent the battery from
discharging through the internal OVP crowbar transistor. The diode must be mounted
on a suitably-rated heatsink to prevent its case temperature from exceeding the
manufacturer's maximum limits.

7.2 LOAD

CONSIDERATIONS

Properly rated diodes should be used to protect the power supply from damage while
driving inductive loads.

7.2.1 Inductive

Loads

To prevent damage to the power supply from inductive kickback, connect a diode (rated
at greater than the supply’s output voltage and current) across the output.