beautypg.com

AMETEK DCS-E 3kW Series User Manual

Page 62

background image

Advanced Operation

Sorensen DCS-E Series 3kW Supplies

4-18

M362295-01 Rev C

AC/DC S

HUTDOWN

To activate the Shutdown function using a 12-250 Vac input or a 12-130 Vdc input:

1. Turn off the power supply and disconnect the AC power source. Allow five (5) minutes to

elapse to dissipate stored energy before making connections or resetting switches.

2. Connect the AC or DC source to pin 1 (positive) and pin 2 (return) on the J3 connector

on the rear panel. See Figure 4-16 and Figure 4-17.

3. Set internal switch SW1-8 to select the desired circuit logic as shown in the table below.

Switch SW1-8 Setting

AC/DC Signal Level

Output Condition

OPEN (Positive)

ON

OFF

OFF

ON

CLOSED (Negative)

ON

ON

OFF

OFF

The red S/D (Shutdown) LED on the front panel lights up when the Shutdown circuit is
activated.

Figure 4-16 Using Shutdown with an AC or DC Input (Positive Logic)

Figure 4-17 Using Shutdown with an AC or DC Input (Negative Logic)