Advanced Operation

Sorensen DCS-E Series 3kW Supplies

4-2

M362295-01 Rev C

4.2 CONFIGURING FOR REMOTE PROGRAMMING,

SENSING, AND MONITORING

This section lists switch, connector, and jumper functions for the DCS-E Series (3kW) supply.
Subsequently, it provides a location diagram (Section 4.2.2), in addition to procedures for
resetting the internal jumpers and switches (Section 4.2.3), and for reconfiguring or making
connections to the J3 connector (Section 4.2.4).

You will find remote programming procedures and diagrams covered in more detail in
Section 4.3, remote sensing in Section 3.3, and remote monitoring of readback signals and
status indicators in Section 4.6.

4.2.1 Programming,

Monitoring, and Control Functions

F

RONT

P

ANEL

REM/LOC S

WITCH

You can use the REM/LOC (Remote/Local Programming) switch for remote programming.
When set to REM (Remote Programming), control of BOTH output voltage AND current limit is
passed to external voltage and/or current sources which are connected to the J3 connector.
Resetting the switch to LOC returns the supply to local (front panel) control. See Section 4.3 for
more information about using this switch.

E

XTERNAL

J3 C

ONNECTOR

The external J3 connector provides user access to the following functions:

Remote programming of output voltage OR current limit, and for OVP

Remote monitoring of the following readback signals and status indicators

Readback Signals

Status Indicators

Calibrated output voltage

Thermal shutdown

Calibrated output current

OVP circuit

Remote/local programming mode

Remote programming of the shutdown function using AC, DC, or TTL compatible signals

Remote sensing of output voltage

See Figure 4-1 Connector J3.

WARNING!


Use extreme caution when biasing the output relative to the chassis due to
potential high voltage levels at the output and J3 terminals.