Advanced Operation

Sorensen DCS-E Series 3kW Supplies

4-12

M362295-01 Rev C

4.3.3

Programming Output Current Limit

P

ROGRAMMING

O

UTPUT

C

URRENT

L

IMIT WITH A

0-5 V

DC

S

OURCE

1. Remove the jumpers connecting pins 10 to 11 and 22 to 23 on connector J3.

2. Connect the external programming source between pins 10 (current limit programming

input/positive) and 12 (return).

Varying the programming voltage from 0 to 5 Vdc will cause the current limit to vary from 0 to
100% of the model rating. The output voltage is set locally by adjusting the front panel voltage
control.

Figure 4-8 Programming Output Current Limit with a 0-5 Vdc Source

P

ROGRAMMING

O

UTPUT

C

URRENT

L

IMIT WITH A

0-10 V

DC

S

OURCE

1. Set jumper JMP2 to its A-B location.

2. Remove the jumpers connecting pins 10 to 11 and 22 to 23 on connector J3.

3. Connect the external current programming source between pins 10 (current limit

programming input/positive) and 12 (return).

Varying the programming voltage from 0 to 10 Vdc will cause the output current limit to vary
from 0 to 100% of the model rating. The output voltage is set locally by adjusting the front panel
voltage control.

Note: Resetting internal jumpers may require a recalibration of the programming circuit to

maintain programming accuracy. See Section 6.3 Calibrating for Programming
Accuracy.

Figure 4-9 Programming Output Current Limit with a 0-10 Vdc Source