Section 4 advanced operation, 1 introduction, Advanced operation – AMETEK DCS-E 3kW Series User Manual

Page 45

background image

M362295-01 Rev C

4-1

SECTION 4

ADVANCED OPERATION

4.1 INTRODUCTION

All DCS-E Series power supplies offer the following standard features:

Remote Programming of Output Voltage and Current Limit with 0-5V, 0-10V, 0-1 mA,
and 0-5k ohms (Section 4.3)

Overvoltage Protection (OVP) with front panel controls or 0-5V and 0-10V programming
(Section 4.4)

Programmable Shutdown with AC, DC, or TTL compatible signals and contact closure
(Section 4.5)

Remote Monitoring of Status Indicators for thermal shutdown, OVP status, remote/local
programming mode, and voltage/current mode operation (Section 4.6)

Calibrated Readback Signals for output voltage and output current with selectable 0-5V
or 0-10V scales (Section 4.6)

Multiple Supply Configurations such as series, parallel, and split supply (Section 4.7)

Remote Voltage Sensing (Section 3.3)

Output Voltage Biasing (Section 4.8)

Accessing these features may require that you use one or more of the following procedures:

Using the front panel REM/LOC (Remote/Local Programming) switch.

Reconfiguring the rear panel J3 connector.

Making connections to the J3 connector.

Resetting internal jumpers JMP1 and JMP2.

Resetting internal switch SW1.