AMETEK DCS-E 3kW Series User Manual
Page 68

Advanced Operation
Sorensen DCS-E Series 3kW Supplies
4-24
M362295-01 Rev C
4.7.3
Configuring Multiple Supplies for Split Supply Operation
Split supply operation uses two power supplies to obtain two positive voltages with a common
ground, or to obtain a positive-negative supply.
To obtain two positive voltages, connect the negative output terminals of both supplies
together. The positive output terminals will provide the required voltages with respect to the
common connection. See Figure 4-24.
To obtain a positive-negative supply, connect the negative output terminal of one supply to
the positive output terminal of the second supply. The positive output terminal of the first supply
then provides a positive voltage relative to the common connection while the negative output
terminal of the second supply provides a negative voltage. The current limits can be set
independently. The maximum current available in split supply operation is equal to the model-
rated output of the supplies used. See Figure 4-25.
CAUTION!
To prevent possible damage to the supply, do not connect the remote program
return line of the negative supply to the common connection.
Figure 4-24 Split Supply Operation of Multiple Supplies (Two Positive Voltages)
(Local sense lines shown are default J3 connections.)