beautypg.com

3 specifications, 1 electrical specifications1, 1 electrical specifications – AMETEK DCS-E 3kW Series User Manual

Page 20

background image

Introduction

Sorensen DCS-E Series 3kW Supplies

1-2

M362295-01 Rev C

External Shutdown using AC, DC, or TTL compatible signals (positive or negative logic).

Remote Voltage, Current Limit, and OVP Programming with selectable programming
ranges.

Optional IEEE-488 (GPIB) interface for complete digital remote programming and
readback capability.

1.3 SPECIFICATIONS

1.3.1 Electrical Specifications

1

Models

DCS

8-350E

DCS

12-250E

DCS

20-150E

DCS

40-75E

DCS

55-55E

DCS

60-50E

DCS

80-37E

DCS

150-20E

Output Ratings
Output

Voltage

Output

Current

Output

Power


0-8V
0-350A
2800W


0-12V
0-250A
3000W


0-20V
0-150A
3000W


0-40V
0-75A
3000W


0-55V
0-55A
3025W


0-60V
0-50A
3000W


0-80V
0-37A
2960W


0-150V
0-20A
3000W

Line Regulation

2

Voltage
Current


8 mV
350 mA


12 mV
250 mA


20 mV
150 mA


40 mV
75 mA


55 mV
55 mA


60 mV
50 mA


80 mV
37 mA


150 mV
20 mA

Load Regulation

3

Voltage
Current


8 mV
350 mA


12 mV
250 mA


20 mV
150 mA


40 mV
75 mA


55 mV
55 mA


60 mV
50 mA


80 mV
37 mA


150 mV
20 mA

Meter Accuracy
Voltage

Current


0.09V
4.5A


0.13V
3.5A


0.2V
0.1.6A


0.5V
0.85A


0.65V
0.65A


0.7V
0.6A


0.9V
0.47A


1.6V
0.30A

OVP Adjustment
Range


0.4-8.8V


0.6-13.2V


1-22V


2-44V


2.75-60.5V


3-66V


4-88V


7.5-165V

Output Noise and
Ripple (V)
Rms
p–p
(20 Hz – 20 MHz)



10 mV
100 mV



10 mV
100 mV



10 mV
100 mV



20 mV
100 mV



20 mV
100 mV



20 mV
100 mV



20 mV
100 mV



30 mV
200 mV

Analog
Programming
Linearity
Voltage
Current

80 mV
3500 mA

120 mV
2500 mA

200 mV
1500 mA

400 mV
750 mA

550 mV
550 mA

600 mV
500 mA

800 mV
370 mA

1.5V
200 mA

1

Specifications are warranted over a temperature range of 0–50°C with default local sensing. From 50–70°C, derate 2% per °C.

2

For input voltage variation over the AC input voltage range, with constant rated load.

3

For 0-100% load variation, with constant nominal line voltage.


AC Input: 200-250 Vac at 20 Arms Single Phase or 190-250 Vac at 14 Arms Three Phase

(Output power limited to 2500W for single phase input)

Maximum Voltage Differential from output to safety ground: 150 Vdc