2 rack mounting, 5 ac input power, 1 ac input power connection – AMETEK DCS-E 3kW Series User Manual
Page 28: 2 ac input power requirements
Installation
Sorensen DCS-E Series 3kW Supplies
2-4
M362295-01 Rev C
2.4.2 Rack
Mounting
The supply is designed to fit in a standard 19” equipment rack. Bolt holes in the chassis sides
are provided for rack mount slides such as the ZERO #C300S18 slides. When installing the unit
in a rack, be sure to provide adequate support for the rear of the unit while not obstructing the
ventilation on the top, sides and rear of all units. (See Section 2.4, Location, Mounting, and
Ventilation in this manual).
CAUTION!
Rack mounting bolts must not extend more than
3/16
" into the side of the
power supply.
2.5 AC INPUT POWER
Section 2.5.1 AC Input Power Connection gives instructions for making connections to either
single phase or three phase AC power sources. Order replacement AC input connectors and
contacts using the following part numbers.
Housing
Tyco 641685-1
Chassis-Mounted Parts
Contact Pins
Tyco 350821-1
Connector Housing
Tyco 643267-1
Mating Connector Parts
Contact Pins
Tyco 350821-1
2.5.1
AC Input Power Connection
Before you can use the DCS-E system supply, you must determine your AC input power
requirements and assemble an appropriate line cord and connector. The power supply is
shipped with a kit of connector and strain relief parts which you assemble using the procedures
in this section.
2.5.2
AC Input Power Requirements
This supply may be operated from either a single phase or a three phase AC power source. The
specifications for input voltage, current, and frequency are listed below.
AC Input Voltage Range
Maximum Input Current
Frequency
200-250 Vac Single Phase
20 Arms
47-63 Hz
190-250 Vac Three Phase
14 Arms
47-63 Hz
CAUTION!
The maximum output power must be limited to 2500 Watts when the power
supply is used with a single phase input to avoid tripping the power
supply's input circuit breaker.