eZ8

CPU Core

User Manual

UM012820-0810

WDT Instruction

251

WDT

Definition

Watchdog Timer Refresh.

Syntax

WDT

Operation

None.

Description

Enable the Watchdog Timer by executing the WDT instruction. Each sub-
sequent execution of the WDT instruction refreshes the timer and pre-
vents the Watchdog Timer from timing out. For more information on the
Watchdog Timer, refer to the relevant Product Specification.

Flags

Attributes

C

Unaffected

Z

Unaffected

S

Unaffected

V

Unaffected

D

Unaffected

H

Unaffected

Mnemonic

Destination,
Source

Op
Code
(Hex)

Operand 1 Operand 2 Operand 3

WDT

5F