Slide Ethernet cable through the assembled strain relief unit before crimping on the
RJ45 connector.

Strip cable and configure color code (see section 2.4.5). Use one of the LAN port
weather protection seal stickers – two are provided.

2.3.4 Configuring the Cable

Determine the length of cable that will be required and where the PIM will be located.

Note:

The total length of cable from the Mesh2HT to the Ethernet device cannot exceed

100m (325 feet), however, the PIM can be located anywhere along the overall 100m of
cable. KBC Networks recommends shielded Ethernet cables for the cable connecting the
PIM to the Mesh2HT unit. Any cable exposed to the elements should also be outdoor
rated.

Slide the weatherproof connector over the cable jacket before crimping the connector.
See section 2.3.3 for the strain relief assembly instructions. If needed, see below for
color-code standards to configure the correct type of Ethernet cable.


Ethernet standard straight-through cable configurations used must be configured to one
of the Ethernet standards (568-A or 568-B) in order for the Mesh2HT system to operate
efficiently. Any deviation from one of the two standard configurations can lead to
undesired activity.

Pin out for color codes 568-A and 568-B:

568-A

568-B

1- Green/White

1- Orange/White

2- Solid Green

2- Solid Orange

3- Orange/White

3- Green/White

4- Solid Blue

4- Solid Blue

5- Blue/White

5- Blue/White

6- Solid Orange

6- Solid Green

7- Brown/White

7- Brown/White

8- Solid Brown

8- Solid Brown


A cable configured with the 568-A color code on one end and the 568-B color code on
the other end is an Ethernet standard crossover cable.

Connect the RJ45 connector into the Mesh2HT’s LAN port. Slide the strain relief back
up the cable to the threaded portion on the LAN port of the device and screw it into
the host/AP or client and tighten.

Tighten the clamping nut until the Ethernet cable is secured in the connector. The
weatherproof strain relief should be tight to the case but the rubber grommet opening
should remain loose enough for the cable to wiggle slightly. This will allow for
condensation release.

RJ45

Connector