PowerPlay Early Power Estimator Spreadsheet Inputs

also verifies that the V

CCIO

levels match the I/O standards for each I/O

bank. If there is a discrepancy, it is displayed in the Bank Voltage Check
column, as shown in

Figure 3–14

.

Figure 3–13. I/O Standard Verification

Figure 3–14. PowerPlay Early Power Estimator Spreadsheet Checks for V

CCIO

Inconsistencies

The PowerPlay early power estimator shows the I

C C I O

listed for each

bank. Select the V

CCIO

in the V

CCIO

column. The PowerPlay early power

estimator checks whether or not your selected V

CCIO

is acceptable based

on the I/O standard and I/O bank combination in the listed modules. If