1 safety characteristic data, Safety characteristic data – Pilz PSSu K F FCU User Manual
Page 39

Technical details
Operating Manual PSSu K F FCU
1002391-EN-04
39
Environmental data
312435
Max. operating height above sea level
5000 m
Airgap creepage
In accordance with the standard
EN 60664-1
Overvoltage category
II
Pollution degree
2
Protection type
In accordance with the standard
EN 60529
Mounting (e.g. cabinet)
IP54
Housing
IP20
Mechanical data
312435
Material
Bottom
PC
Front
PC
Labelling bracket (accessories)
PC
Connection type
Connector strip
Mounting type
plug in
Conductor cross section with spring-loaded terminals:
flexible with/without crimp connector
0,20 - 1,00 mm², 22 - 18 AWG
Spring-loaded terminals: Terminal points per connec-
tion
1
Stripping length
8 mm
Dimensions
Height
128,9 mm
Width
56,0 mm
Depth
56,0 mm
Depth incl. connector (accessories)
69,5 mm
Depth incl. labelling bracket (accessories)
83,5 mm
Weight
166 g
The standards current on 2012-02 apply.
Safety characteristic data
Unit
Operating
mode
EN ISO
13849-1: 2008
PL
EN ISO
13849-1: 2008
Category
EN IEC 62061
SIL CL
EN IEC 62061
PFH
D
[1/h]
EN ISO
13849-1: 2008
T
M
[year]
Logic
Logic
–
PL e
Cat. 4
SIL CL 3
1,36E-10
20
Input
Digital inputs
1-channel
PL d
Cat. 2
SIL CL 2
3,55E-09
20
Digital inputs
2-channel
PL e
Cat. 4
SIL CL 3
7,31E-11
20
Digital inputs
1-ch., pulsed
light beam
device
PL e
Cat. 4
SIL CL 3
3,55E-10
20
8.1