beautypg.com

Hanna Instruments HI 98280 User Manual

Page 16

background image

16

(*) Without remarks. When using remarks the maximum number of samples decreases.

SALINITY

Range

Range

Range

Range

Range

0.00 to 70.00 PSU (extended Practical Salinity Scale)

Resolution

Resolution

Resolution

Resolution

Resolution

0.01 PSU

Accuracy

Accuracy

Accuracy

Accuracy

Accuracy

±2% of reading or ±0.01 PSU whichever is greater

Calibration

Calibration

Calibration

Calibration

Calibration

1 custom point

SEAWATER SPECIFIC GRAVITY
Range

Range

Range

Range

Range

0.0 to 50.0

σ

t

,

σ

0

,

σ

15

Resolution

Resolution

Resolution

Resolution

Resolution

0.1

σ

t

,

σ

0

,

σ

15

Accuracy

Accuracy

Accuracy

Accuracy

Accuracy

± 1

σ

t

,

σ

0

,

σ

15

Calibration

Calibration

Calibration

Calibration

Calibration

Based on conductivity or salinity calibration

ATMOSPHERIC PRESSURE

Range

Range

Range

Range

Range

450 to 850 mmHg; 17.72 to 33.46 inHg;

600.0 to 1133.2 mbar; 8.702 to 16.436 psi;
0.5921 to 1.1184 atm; 60.00 to 113.32 kPa

Resolution

Resolution

Resolution

Resolution

Resolution

0.1 mmHg; 0.01 inHg; 0.1 mbar

0.001 psi; 0.0001 atm; 0.01 kPa

Accuracy

Accuracy

Accuracy

Accuracy

Accuracy

±3 mmHg within ±15°C from calibration temperature

Calibration

Calibration

Calibration

Calibration

Calibration

Automatic at 1 custom point

GENERAL CHARACTERISTICS
T

TT

TTemperature Compensation

emperature Compensation

emperature Compensation

emperature Compensation

emperature Compensation Automatic from -5 to 55 °C (23 to 131 °F)

Logging Memory(*)

Logging Memory(*)

Logging Memory(*)

Logging Memory(*)

Logging Memory(*)

Up to 60,000 samples with 13 measurements each;

up to 45,000 samples with 15 measurements each (w/GPS)

Logging Interval

Logging Interval

Logging Interval

Logging Interval

Logging Interval

1 second to 3 hours

PC Interface

PC Interface

PC Interface

PC Interface

PC Interface

USB (with HI 929828 software)

W

W

W

W

Waterproof P

aterproof P

aterproof P

aterproof P

aterproof Protection

rotection

rotection

rotection

rotection

Meter IP67, Probe IP68

Environment

Environment

Environment

Environment

Environment

0 to 50 °C (32 to 122 °F); RH 100 %

P

PP

PPower Supply

ower Supply

ower Supply

ower Supply

ower Supply

4 x 1.2 V rechargeable C size, Ni-MH batteries

or 4 x 1.5 V alkaline, C size batteries

Dimensions/W

Dimensions/W

Dimensions/W

Dimensions/W

Dimensions/Weight

eight

eight

eight

eight

Meter

221x115x55 mm (8.7x4.5x2.2”) / 750 g (26.5 oz.)

Probe (w/out cable)

L=270 (10.6”), dia=46 mm (1.8”) / 750 g (26.5 oz.)