:READ[1..n][:SCALar]:POWer:DC?

Description

This query returns the power measured at the

instrument's input port.

This command is an event and has no associated

*RST condition or query form.

Syntax

:READ[1..n][:SCALar]:POWer:DC?

Parameter(s)

None

Response Syntax

Response(s)

PowerMeasurement:
The response data syntax for

is defined as a

NUMERIC RESPONSE DATA> element.

The response represents

the current input power.

Example(s)

READ:SCAL:POW:DC? Returns -1.254000E+001

READ:SCAL:POW:DC? Returns

9221120237577961472 = (UNDERRANGE)

READ:SCAL:POW:DC? Returns

9221120238114832384 = (OVERRANGE)