Working with OTDR Files

70

FastReporter

Creating Bidirectional OTDR Files

Creating Bidirectional Measurement Files

You can combine unidirectional measurements into a bidirectional
measurement file. It is possible to use both single-wavelength and
multiwavelength measurements. FastReporter matches the wavelengths.

The A->B and B->A measurement files must respect the following criteria:

To create bidirectional files in FastReporter, you must first match A->B files
with B->A files. For information on file matching, refer to Matching Files on
page 65. Cha
nges made to event matching tolerances will effect
bidirectional event table results.

Item

To be valid...

Pulse width

Must be identical for both measurement files.

Fiber types

Use only measurements acquired using
singlemode fibers.

Wavelengths

Must be identical for both measurements.

Measurement file

Both must be unidirectional files.