Description of OTDR Event Types

212

FastReporter

Merged Reflective Event

Merged Reflective Event

This symbol denotes a reflective event combined with one or more other
reflective events. It also indicates the total loss produced by the merged
reflective events following it in the events table.

³

A Merged Reflective Event is composed of reflective events. Only the
Merged Reflective Event is attributed a number in the events table, not
the reflective subevents composing it, if they are displayed.

³

Reflective events may indicate the presence of connectors,
mechanical splices, or poor-quality fusion splices or cracks.

³

A reflectance value is specified for all merged reflective events and
indicates the maximum reflectance for the merged event.

A reflectance value is also displayed for each subevent composing the
Merged Reflective Event.

Reflective events

Point A

Point B

Merged Reflective event position

Total loss (

dB)

Reflected power
(dB)

Distance
(km)