Ditch Witch JT100AT User Manual
Page 88

JT100/JT100 All Terrain Operator’s Manual
Prepare - 87
Plan Bore Path
CMW
©
Pipe-By-Pipe Bend Limits - Power Pipe
®
Forged
Pipe
(C)
Forward (B)
Deflection (A)
Pipe
(C)
Forward (B)
Deflection (A)
1
0 ft 7 in (0.2 m)
14 ft 12 in (4.6 m)
12
76 ft 8 in (23.4 m)
155 ft 12 in (47.5 m)
2
2 ft 3 in (0.7 m)
29 ft 11 in (9.1 m)
13
88 ft 11 in (27.1 m)
164 ft 8 in (50.2 m)
3
5 ft 1 in (1.6 m)
44 ft 7 in (13.6 m)
14
101 ft 9 in (31 m)
172 ft 5 in (52.6 m)
4
9 ft 1 in (2.8 m)
59 ft 1 in (18 m)
15
115 ft 1 in (35.1 m)
179 ft 2 in (54.6 m)
5
14 ft 1 in (4.3 m)
73 ft 2 in (22.3 m)
16
128 ft 12 in (39.3 m)
184 ft 11 in (56.4 m)
6
20 ft 2 in (6.2 m)
86 ft 11 in (26.5 m)
17
143 ft 3 in (43.7 m)
189 ft 6 in (57.8 m)
7
27 ft 4 in (8.3 m)
100 ft 1 in (30.5 m)
18
157 ft 10 in (48.1 m)
193 ft 1 in (58.8 m)
8
35 ft 5 in (10.8 m)
112 ft 9 in (34.4 m)
19
172 ft 7 in (52.6 m)
195 ft 6 in (59.6 m)
9
44 ft 6 in (13.6 m)
124 ft 8 in (38 m)
20
187 ft 7 in (57.2 m)
196 ft 9 in (59.9 m)
10
54 ft 8 in (16.6 m)
135 ft 11 in (41.4 m)
21
197 ft 0 in (60 m)
197 ft 0 in (60 m)
11
65 ft 2 in (19.9 m)
146 ft 4.5 in (44.6 m)
Pipe 10 is illustrated.