Diagnostic Codes
CMW
©
144
charge air cooler sensor error
fan may turn fully on and code is
stored
non-
essential
151
drill joystick left/right out of range
rotation, cruise control and drive are
blocked and code is stored
essential
152
drill joystick forward/backward out of
range
thrust, cruise control and drive are
blocked and code is stored
essential
153
no continuity to inner rotation jog pot
code is stored
non-
essential
154
drilling fluid potentiometer out of
range
code is stored
essential
155
rotation potentiometer is out of range
code is stored
non-
essential
215
no continuity to float position sensor
assisted makeup is blocked and code
is stored
non-
essential
221
system voltage is below 9V
code is stored
non-
essential
222
inner rotation position sensor not
changing
dither compensation is blocked
non-
essential
233
drill and drive inputs both on
drill and drive are blocked and code is
stored
essential
234
add pipe and remove pipe inputs both
on
add pipe and remove pipe are
aborted, blocked and code is stored
non-
essential
235
front home and rear home inputs both
on
add pipe and remove pipe are
aborted, blocked and code is stored
non-
essential
241
shuttles not responding correctly
add pipe or remove pipe is aborted,
blocked and code is stored
non-
essential
244
rotation not responding correctly
auto carve mode is replaced with
manual carve
non-
essential
245
FRAM parameter table length change
code is stored
non-
essential
254
error reading setup table information
add pipe and remove pipe are
aborted, blocked and code is stored
essential
255
undefinable diagnostic code reported
code is stored
non-
essential
Code
Condition
Result
Severity